The recorded steSta.Q_flow channel spans -2,269 to 503.619 W in this reference run. It starts at 503.619 and ends at 0. The first recorded maximum occurs at 0 seconds and the first minimum at 804 seconds.

The system being tested

The RWTH Aachen University E.ON Energy Research Center publishes the AixLib test named PrescribedOutlet. The source file places it under Fluid, Interfaces. We used the 101 stored values for steSta.Q_flow over the interval 0 to 1,200 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 25 recorded variables. Alongside the primary output there are heaHigPow.sta_a.T, heaHigPow.sta_b.T, cooLimPow.sta_a.T, cooLimPow.sta_b.T, heaCooUnl.sta_a.T. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

The companion channel cooLimPow.Q_flow covers -1,000 to 5,334 W. At 936 s, the primary value is -2,269 and the companion is 5,334. Their signed difference is -7,604 W, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Prescribed outlet state. The simulated steSta.Q_flow channel runs from -2,269 to 503.619 W over 1,200 seconds.
Prescribed outlet state. The simulated steSta.Q_flow channel runs from -2,269 to 503.619 W over 1,200 seconds. Figure by Industry Applied.

Reproduce the calculation

Integrating the signed steSta.Q_flow samples by the trapezoidal rule gives -0.1576 kWh over 1,200 seconds. For each pair, average the two powers in watts and multiply by the interval in seconds. Sum the watt-seconds and divide by 3,600,000. This value refers to the selected simulation connector and should be assigned to a physical load only after confirming the boundary and sign.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

steSta.Q_flow (W)

cooLimPow.Q_flow (W)

0

503.6189

0

240

503.6189

-503.6253

480

503.6189

-503.6181

492

503.6189

-503.6181

504

-1010.035

-1000

720

-1010.035

-1000

804

-2269.317

398.5863

960

-2269.317

5334.289

1200

0

0

What to check on site

Identify which part of the system the selected output represents, and retain the surrounding boundary conditions. Compare the same event and operating duty in both records. Record the equipment configuration if a later change could alter the test result.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.