The rooA.T trace covers 29.901 to 30 °C, a temperature span of 0.0986 K. The first recorded maximum occurs at 0 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named ZonalFlow. The source file places it under Airflow, Multizone. We used the 101 stored values for rooA.T over the interval 0 to 3,600 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name rooA (Mixing Volume), rooB (Mixing Volume), ACS (Constant), zonFlo (Zonal Flow ACS). The source declares volA = 100, volB = 1. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel rooB.T covers 293.15 to 303.051 K. At 0 s, the primary value is 303.15 and the companion is 293.15. Their signed difference is 10 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Prescribed air exchange between two volumes. The simulated rooA.T channel runs from 303.051 to 303.15 K over 3,600 seconds.
Prescribed air exchange between two volumes. The simulated rooA.T channel runs from 303.051 to 303.15 K over 3,600 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 36 seconds. Subtracting 303.15 from 303.103 gives -0.04745 K. Its location brackets the change within one saved interval of 36 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

rooA.T (K)

rooB.T (K)

0

303.15

293.15

36

303.1025

297.9258

540

303.0514

303.0509

720

303.0514

303.0514

1440

303.0514

303.0514

2160

303.0514

303.0514

2880

303.0514

303.0514

3600

303.0514

303.0514

What to check on site

Identify the connected zones, pressure references and flow direction. Changing a door, leakage path or boundary condition can redistribute the same total flow between branches. A differential pressure alone cannot establish the air quantity reaching a zone.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.