The preHeatCoil.TMix trace covers 5 to 20 °C, a temperature span of 15 K. The first recorded maximum occurs at 972 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named PreHeatCoil. The source file places it under Dual Fan Dual Duct, Controls. We used the 101 stored values for preHeatCoil.TMix over the interval 0 to 10,800 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name TSupSet (Constant), TAirSup (Constant), TMix (Trapezoid). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel preHeatCoil.yVal starts at 0.1, ends at 1 and has a recorded range of 0 to 1 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 0 to 108 seconds. Subtracting 278.15 from 279.95 gives 1.8 K. Its location brackets the change within one saved interval of 108 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | preHeatCoil.TMix (K) | preHeatCoil.yVal (source units) |
|---|---|---|
0 | 278.15 | 0.1 |
108 | 279.95 | 0.19 |
972 | 293.15 | 0.91 |
2160 | 287.15 | 0 |
4320 | 290.15 | 1 |
6480 | 278.15 | 1 |
8640 | 293.15 | 1 |
10800 | 278.15 | 1 |
What to check on site
Compare fuel or electrical input with useful heat at a declared delivery boundary. Include the warm-up interval and any period on standby. Separate a temperature setpoint from the measured outlet and keep auxiliary energy in a stated part of the balance.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.