The recorded PCon.y channel spans 3 to 4.999 source units in this reference run. It starts at 3 and ends at 4.999. The first recorded maximum occurs at 5,270,400 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named LinearInput. The source file places it under Controls, Predictors. We used the 101 stored values for PCon.y over the interval 0 to 5,270,400 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name TOut (Ramp), POffSet (Constant), PCon (Add), err (Add). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel baseLoad.PPre[1] starts at 0, ends at 4.999 and has a recorded range of 0 to 4.999 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Predictors linear input. The simulated PCon.y channel runs from 3 to 4.999 source units over 5,270,400 seconds.
Predictors linear input. The simulated PCon.y channel runs from 3 to 4.999 source units over 5,270,400 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 2,687,904 to 2,740,608 seconds. Subtracting 4.019 from 4.04 gives 0.02049 source units. Its location brackets the change within one saved interval of 52,704 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

PCon.y (source units)

baseLoad.PPre[1] (source units)

0

3

0

1054080

3.398907

3.398907

2108160

3.79918

3.79918

2687904

4.019125

4.019125

2740608

4.039618

4.039618

3162240

4.199453

4.199453

4216320

4.599727

4.599727

5270400

4.998634

4.998634

What to check on site

Record each condition, calculated request and issued output as separate tags. Keep timestamps and the sample or event rule with the export. A stable displayed value may be held by logic after the measured input has changed.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.