The dp trace ranges from -2.8284 Pa to 2.8284 Pa across 101 saved checkpoints. It begins at -2.8284 Pa and finishes at 2.8284 Pa after 4 s of test time. The source identifies the channel scale as Pa. Its first saved maximum occurs at 2 s.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named PowerLaw_m_flow_DerivativeCheck2. The source file places it under Fluid, Flow Models. We used the 101 stored values for dp over the interval -2 to 2 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name m_flow (Mass Flow Rate), dp (Pressure Difference), dp_comp (Pressure Difference), der_dp (Real). The source declares k = 0.5, m_flow_turbulent = 0.1. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

At 1.8 s, dp is 1.7605 Pa and dp_comp is 1.7605 Pa. Subtracting the second value from the first gives -7.153e-07 Pa. This is their largest recorded absolute separation. A difference between an inlet and an outlet, or between a command and a response, need not be a measurement error.

Power law mass flow derivative check2. The simulated dp channel runs from -2.828 to 2.828 Pa over 4 seconds.
Power law mass flow derivative check2. The simulated dp channel runs from -2.828 to 2.828 Pa over 4 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from -2 to -1.96 seconds. Subtracting -2.828 from -2.583 gives 0.2458 Pa. Its location brackets the change within one saved interval of 0.04 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

dp (Pa)

dp_comp (Pa)

-2

-2.828427

-2.828427

-1.96

-2.582631

-2.58263

-1.2

-0.2839393

-0.2839391

-0.4

-0.00471575

-0.004715465

0.4

0.00471575

0.004716057

1.2

0.2839393

0.28394

2

2.828427

2.828428

What to check on site

Identify which part of the system the selected output represents, and retain the surrounding boundary conditions. Compare the same event and operating duty in both records. Record the equipment configuration if a later change could alter the test result.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Units in the source model

The component declarations identify the scale of the exported variables. In this run, dp_comp uses Pa. Keep the exact channel name and unit together when exporting data to a historian. Read the component definition.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.