The recorded sca1.y[1] channel spans -0.9997 to 1 source units in this reference run. It starts at 1 and ends at -0.8391. The first recorded maximum occurs at 0 seconds and the first minimum at 9.4 seconds.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named Scatter. The source file places it under Utilities, Plotters. We used the 101 stored values for sca1.y[1] over the interval 0 to 10 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name sca (Scatter), sine (Real Expression), cosine (Real Expression), sca1 (Scatter). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel sca1.y[2] covers 0.000153 to 1 source units. At 9.4 s, the primary value is -0.9997 and the companion is 0.9994. Their signed difference is -1.999 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.
Reproduce the calculation
The largest absolute change between consecutive stored points appears from 7.8 to 7.9 seconds. Subtracting 0.05396 from -0.046 gives -0.09996 source units. Its location brackets the change within one saved interval of 0.1 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | sca1.y[1] (source units) | sca1.y[2] (source units) |
|---|---|---|
0 | 1 | 1 |
2 | -0.4161468 | 0.1731782 |
4 | -0.6536436 | 0.42725 |
6 | 0.9601703 | 0.921927 |
7.8 | 0.05395561 | 0.002911212 |
7.9 | -0.04600203 | 0.002116189 |
8 | -0.1455 | 0.02117026 |
9.4 | -0.999693 | 0.9993862 |
10 | -0.8390715 | 0.704041 |
What to check on site
Identify which part of the system the selected output represents, and retain the surrounding boundary conditions. Compare the same event and operating duty in both records. Record the equipment configuration if a later change could alter the test result.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.