The pip.vol[1].T trace covers 20 to 49.999 °C, a temperature span of 29.999 K. The first recorded maximum occurs at 106.8 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named Pipe. The source file places it under Fluid, Fixed Resistances. We used the 101 stored values for pip.vol[1].T over the interval 0 to 120 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name senTem (Temperature Two Port), senTem1 (Temperature Two Port). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel pip.vol[5].T covers 293.15 to 323.14 K. At 15.6 s, the primary value is 319.955 and the companion is 295.455. Their signed difference is 24.5 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Pipe with multiple segments. The simulated pip.vol[1].T channel runs from 293.15 to 323.149 K over 120 seconds.
Pipe with multiple segments. The simulated pip.vol[1].T channel runs from 293.15 to 323.149 K over 120 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 1.2 to 2.4 seconds. Subtracting 295.452 from 300.015 gives 4.563 K. Its location brackets the change within one saved interval of 1.2 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

pip.vol[1].T (K)

pip.vol[5].T (K)

0

293.15

293.15

1.2

295.452

293.1499

2.4

300.0146

293.15

24

322.2427

301.383

48

323.1239

318.2221

72

323.1479

322.5892

96

323.1486

323.0998

106.8

323.1487

323.1304

120

323.1487

323.1405

What to check on site

Distinguish the component characteristic from the installed system response. Record the pressure or temperature on both sides as applicable, the direction of flow and the actuator command. Compare a change at constant demand with one caused by a different load.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.