The pla1.y trace ranges from -205.089 to 1,371 across 101 saved checkpoints. It begins at 0 and finishes at 1.4894 after 100 s of test time. The reference export does not state a verified engineering unit for this value. Use its native scale when comparing another run of the same model.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named PIDWithResetScale. The source file places it under Controls, OBC, CDL, Reals. We used the 101 stored values for pla1.y over the interval 0 to 100 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name pulse (Pulse), pidSca (PID With Reset), pla1 (Integrator With Reset), resVal (Constant). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
At 1 s, pla1.y reads 515.59 and pidSca.y reads 0.47894. Across the run, the second channel ranges from -0.2615 to 1. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.
Reproduce the calculation
The largest absolute change between consecutive stored points appears from 0 to 1 seconds. Subtracting 0 from 515.59 gives 515.59 source units. Its location brackets the change within one saved interval of 1 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | pla1.y (source units) | pidSca.y (source units) |
|---|---|---|
0 | 0 | 1 |
1 | 515.5903 | 0.4789353 |
4 | 1371.008 | 0.03256407 |
20 | 990.6621 | -0.002884964 |
40 | -2.417987 | -0.0156599 |
60 | 972.3362 | -0.04528041 |
80 | -152.2427 | -0.1012855 |
81 | -205.0886 | -0.007955091 |
100 | 1.489431 | -0.001741874 |
What to check on site
The largest change in pla1.y between saved samples lies between simulation times 0 s and 1 s. The channel moves from 0 to 515.59 across that interval. A finer export is needed to resolve what happens between those observations.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.