The published pvt.PEle signal spans 0 to 1,170.017 W in the reference run. It starts at 0 and finishes at 0. The signed change between those endpoint samples is 0 W.

What the reference test measures

The AixLib model named PhotovoltaicThermal comes from the RWTH Aachen University E.ON Energy Research Center. The saved result covers simulation time 1.037e+07 to 1.054e+07 seconds. Industry Applied extracted 101 checkpoints for pvt.PEle and kept the original signed values. The regular output spacing is 1,728 seconds. The solver may take different internal steps.

The model definition identifies pvt (EN12975 Curves). These component names let a reader trace the plotted tags to their owning blocks before reproducing the result.

Reading the two channels

At 1.05e+07 seconds, pvt.PEle is 1,170.017 and pvt.vol[1].heatPort.Q_flow is 2,418.393. Subtracting the second channel from the first gives -1,248.377 W, the largest absolute separation on their common saved grid. The channels have distinct roles in the model, so this difference describes the two traces and is not a calibrated instrument error.

Photovoltaic-thermal collector output. In the simulated PhotovoltaicThermal case, pvt.PEle ranges from 0 to 1,170.017 W over 172,800 seconds.
Photovoltaic-thermal collector output. In the simulated PhotovoltaicThermal case, pvt.PEle ranges from 0 to 1,170.017 W over 172,800 seconds. Figure by Industry Applied.

Reproducing the largest recorded change

Between the stored points at 1.041e+07 and 1.041e+07 seconds, pvt.PEle changes from 246.282 to 495.669. Subtracting the earlier reading gives +249.387 W. This interval contains the largest absolute point-to-point change in the saved primary channel. A faster excursion followed by recovery could fit entirely between the two records.

The extrema in the table and figure are extrema of the stored series. A solver’s internal peak, a field logger’s alarm value and a maximum derived from this export can differ. Preserve the sampling settings when comparing results.

Worked data

Simulation time (s)

pvt.PEle (W)

pvt.vol[1].heatPort.Q_flow (W)

1.0368e+07

0

-191.6602

1.040602e+07

246.2822

525.2289

1.040774e+07

495.6689

1018.383

1.04112e+07

831.3568

1740.388

1.04544e+07

0

-43.18095

1.04976e+07

1101.189

2268.718

1.049933e+07

1170.017

2418.393

1.05408e+07

0

-98.05733

Applying the result to an operating site

A collector can produce electricity while exchanging heat with its fluid circuit. Local heat flow in a single model cell is not the whole collector’s useful thermal output. Calculate the latter from inlet and outlet fluid conditions over the entire array boundary.

For a local engineering comparison, write the measurement boundary, operating duty and instruments into the test record. Select comparable load or weather periods, then compare the measured trace with the simulated quantities. Establish a local acceptance tolerance using the intended duty and measurement uncertainty.

Model and data sources

Model definition. Original numerical reference series. Simulation and plotting script. Source project. Download the worked checkpoints as CSV.