The lowest observed group mean is 758.683 for run Id group 5 to 8. The highest is 958.761 for group 9 to 12, a difference of 200.078 on the source response scale. Across all 5,473 numeric records the response median is 849.

What was measured

The TIETJEN data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as phosphorus Screen Light Intensity. It preserves the source scale and its sign. The file contains 2 numeric fields per accepted row.

Spread across the original readings

The two endpoint groups have 1,456 and 1,458 observations. Their medians are 758 and 953, respectively. The figure groups the original entries by the recorded run Id value. Where there are more than eight distinct settings, it groups them at empirical quartiles and labels each band with its observed endpoints.

Phosphorus screen intensity over production runs. The lowest and highest group means are 758.683 and 958.761 on the source response scale.
Phosphorus screen intensity over production runs. The lowest and highest group means are 758.683 and 958.761 on the source response scale. Figure by Industry Applied.

One row you can check

To check a real observation, take numeric row 1,895 after the header. Its response is 849. The overall arithmetic mean is 863.622, so this observation is -14.622 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 237, calculated by subtracting 743 from 980.

The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.

Worked data

run Id group

Observations

Mean response

Median response

Minimum response

Maximum response

1 to 4

1475

861.2685

844

524

1379

5 to 8

1456

758.6834

758

517

1177

9 to 12

1458

958.7613

953

644

1372

13 to 15

1084

879.809

875

532

1382

Implications for an industrial comparison

A production acceptance sample should identify the item, instrument, operator and measurement method before the result is pooled. Document fixture setup and any intermediate processing. Repeatability from one instrument and reproducibility across operators or locations require different comparison groups.

Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.

Source file and worked data

The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.