The archived response ranges from 804 to 7,479. The median is 4,100 and the central half of the measurements extends from 3,424 to 4,754. Those figures use all 989 numeric observations in this source series and retain its original measurement scale.

What was measured

The LUTHER data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as response--pendulum angle. It preserves the source scale and its sign. The file contains 1 numeric field per accepted row.

Spread across the original readings

The tenth percentile is 2,633 and the ninetieth is 5,521. They provide a narrower description of the typical spread than the minimum and maximum. The largest and smallest observed records are separated by 6,675. This is the range of this sample, rather than a guaranteed operating envelope.

Pendulum-angle precision measurement. The 25th, 50th and 75th percentiles of the measurements are 3,424, 4,100 and 4,754.
Pendulum-angle precision measurement. The 25th, 50th and 75th percentiles of the measurements are 3,424, 4,100 and 4,754. Figure by Industry Applied.

One row you can check

To check a real observation, take numeric row 644 after the header. Its response is 4,100. The overall arithmetic mean is 4,082, so this observation is 17.642 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 1,330, calculated by subtracting 3,424 from 4,754.

The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.

Worked data

Percentile

Observed response (source scale)

Number of numeric rows

0

804

989

10

2633.2

989

25

3424

989

50

4100

989

75

4754

989

90

5521.2

989

100

7479

989

Implications for an industrial comparison

A production acceptance sample should identify the item, instrument, operator and measurement method before the result is pooled. Document fixture setup and any intermediate processing. Repeatability from one instrument and reproducibility across operators or locations require different comparison groups.

Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.

Source file and worked data

The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.

Cover photograph by RDNE Stock project, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.