The recorded weaDat.weaBus.TDryBul temperature spans 3.476 °C to 29.9 °C in this simulation. That is a change of 26.424 K. The first saved maximum occurs at 13,188,096 s. The source trace and download retain absolute temperatures in kelvin.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named OverAYear_usingOneYearData. The source file places it under Boundary Conditions, Weather Data. We used the 101 stored values for weaDat.weaBus.TDryBul over the interval 0 to 36,633,600 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name weaDat (Reader TMY3). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The primary channel spends 17.8% of its saved checkpoints at or above 289.838 K, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 286.565 K. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.

Over a year using one year data. The simulated weaDat.weaBus.TDryBul channel runs from 276.626 to 303.05 K over 36,633,600 seconds.
Over a year using one year data. The simulated weaDat.weaBus.TDryBul channel runs from 276.626 to 303.05 K over 36,633,600 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 12,821,760 to 13,188,096 seconds. Subtracting 286.37 from 303.05 gives 16.68 K. Its location brackets the change within one saved interval of 366,336 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

weaDat.weaBus.TDryBul (K)

0

280.35

7326720

284.15

1.282176e+07

286.37

1.31881e+07

303.05

1.465344e+07

291.89

2.198016e+07

291.17

2.930688e+07

285.95

3.077222e+07

276.626

3.66336e+07

282.15

What to check on site

Check the time reference, location and receiving plane for each environmental input. Two measured series can differ because one records horizontal exposure and the other a tilted surface. A comparison needs the same averaging interval and geometric definition.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.