The recorded asyNor.CpAct channel spans -0.9135 to 0.4067 source units in this reference run. It starts at 0.4 and ends at 0.4. The first recorded maximum occurs at 5.2 seconds and the first minimum at 12.4 seconds.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named Outside_CpData_Angles. The source file places it under Fluid, Sources. We used the 101 stored values for asyNor.CpAct over the interval 0 to 20 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name symNor (Outside Cp Data), asyNor (Outside Cp Data), asyWes (Outside Cp Data), symWes (Outside Cp Data). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel symNor.CpAct covers -0.3608 to 0.4 source units. At 12.4 s, the primary value is -0.9135 and the companion is -0.3164. Their signed difference is -0.5971 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 13.2 to 13.4 seconds. Subtracting -0.4909 from -0.3333 gives 0.1577 source units. Its location brackets the change within one saved interval of 0.2 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | asyNor.CpAct (source units) | symNor.CpAct (source units) |
|---|---|---|
0 | 0.4 | 0.4 |
4 | 0.4 | 0.4 |
5.2 | 0.4067008 | 0.3897664 |
8 | -0.3548 | -0.3548 |
12 | -0.864 | -0.3548 |
12.4 | -0.913536 | -0.3164383 |
13.2 | -0.4909311 | -0.08807353 |
13.4 | -0.3332733 | -0.01462066 |
16 | 0.4 | 0.4 |
20 | 0.4 | 0.4 |
What to check on site
Check the time reference, location and receiving plane for each environmental input. Two measured series can differ because one records horizontal exposure and the other a tilted surface. A comparison needs the same averaging interval and geometric definition.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.