The recorded defInf.attFlo.heaPorFro.T temperature spans 1.681 °C to 20 °C in this simulation. That is a change of 18.319 K. The first saved maximum occurs at 0 s. The source trace and download retain absolute temperatures in kelvin.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named Infiltration. The source file places it under Thermal Zones, Energy Plus 24 2 0, Thermal Zone. We used the 101 stored values for defInf.attFlo.heaPorFro.T over the interval 0 to 86,400 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name defInf (Radiant Heating Cooling T Room), higInf (Radiant Heating Cooling T Room). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
At 33,696 s, defInf.attFlo.heaPorFro.T is 278.12 K and higInf.attFlo.heaPorFro.T is 274.009 K. Subtracting the second value from the first gives 4.1114 K. This is their largest recorded absolute separation. A difference between an inlet and an outlet, or between a command and a response, need not be a measurement error.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 0 to 864 seconds. Subtracting 293.15 from 292.051 gives -1.099 K. Its location brackets the change within one saved interval of 864 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | defInf.attFlo.heaPorFro.T (K) | higInf.attFlo.heaPorFro.T (K) |
|---|---|---|
0 | 293.15 | 293.15 |
864 | 292.0511 | 292.0384 |
17280 | 283.0038 | 279.5233 |
34560 | 278.0626 | 273.9538 |
51840 | 277.99 | 274.4794 |
69120 | 276.2924 | 273.6198 |
86400 | 274.831 | 272.9204 |
What to check on site
Identify the connected zones, pressure references and flow direction. Changing a door, leakage path or boundary condition can redistribute the same total flow between branches. A differential pressure alone cannot establish the air quantity reaching a zone.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.