The recorded structure.TSensor[1] channel spans 282.907 to 293.15 source units in this reference run. It starts at 293.15 and ends at 282.907. The first recorded maximum occurs at 0 seconds and the first minimum at 2,000,000 seconds.
The system being tested
The KU Leuven IDEAS project publishes the IDEAS test named NoVentilation. The source file places it under Templates. We used the 101 stored values for structure.TSensor[1] over the interval 0 to 2,000,000 seconds. This is a simulated test with specified inputs and boundaries.
The reference file contains 3 recorded variables. Alongside the primary output there are structure.TSensor[1], structure.TSensor[2], structure.TSensor[3]. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.
Compare the recorded channels
The companion channel structure.TSensor[2] covers 282.403 to 293.15 source units. At 2,000,000 s, the primary value is 282.907 and the companion is 282.403. Their signed difference is 0.5042 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.
![Out ventilation system. The simulated structure.TSensor[1] channel runs from 282.907 to 293.15 source units over 2,000,000 seconds.](https://static.wixstatic.com/media/21e41b_f62ff41f022f466bb0d99dd049f41a35~mv2.png/v1/fill/w_616,h_345,al_c,q_85,enc_auto/21e41b_f62ff41f022f466bb0d99dd049f41a35~mv2.png)
Reproduce the calculation
The largest absolute change between consecutive stored points appears from 1,760,000 to 1,780,000 seconds. Subtracting 283.783 from 284.535 gives 0.7523 source units. Its location brackets the change within one saved interval of 20,000 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | structure.TSensor[1] (source units) | structure.TSensor[2] (source units) |
|---|---|---|
0 | 293.15 | 293.15 |
400000 | 289.387 | 289.496 |
800000 | 286.8834 | 286.6887 |
1200000 | 285.3743 | 285.0913 |
1600000 | 284.6544 | 284.4313 |
1760000 | 283.7831 | 283.3997 |
1780000 | 284.5355 | 284.2336 |
2000000 | 282.9074 | 282.4032 |
What to check on site
Identify the connected zones, pressure references and flow direction. Changing a door, leakage path or boundary condition can redistribute the same total flow between branches. A differential pressure alone cannot establish the air quantity reaching a zone.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.
![Out ventilation system. Range and median of consecutive groups of recorded samples. structure.TSensor[1] (source units). 80k to 1.94M.](/story-art/70d18acbf8e04faaf.webp)