The mHot_flow_set.y trace ranges from 0 to 1.5 across 101 saved checkpoints. It begins at 0 and finishes at 0 after 300 s of test time. The reference export does not state a verified engineering unit for this value. Use its native scale when comparing another run of the same model.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named VariableSource. The source file places it under Fluid, CH Ps, Organic Rankine. We used the 101 stored values for mHot_flow_set.y over the interval 0 to 300 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name orc (Constant Evaporation), souHot (Mass Flow Source T), sinHot (Boundary p T), souCol (Mass Flow Source T). The source declares mHot_flow_nominal = 1, mCol_flow_nominal = 1. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
At 36 s, mHot_flow_set.y reads 0.8 and souHot.T_in reads 370 K. Across the run, the second channel ranges from 345 K to 370 K. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 33 to 36 seconds. Subtracting 0.65 from 0.8 gives 0.15 source units. Its location brackets the change within one saved interval of 3 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | mHot_flow_set.y (source units) | souHot.T_in (K) |
|---|---|---|
0 | 0 | 370 |
33 | 0.65 | 370 |
36 | 0.8 | 370 |
51 | 1.5 | 370 |
60 | 1.5 | 370 |
120 | 1.5 | 360 |
180 | 1.5 | 360 |
240 | 1.5 | 370 |
300 | 0 | 370 |
What to check on site
Compare fuel or electrical input with useful heat at a declared delivery boundary. Include the warm-up interval and any period on standby. Separate a temperature setpoint from the measured outlet and keep auxiliary energy in a stated part of the balance.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Units in the source model
The component declarations identify the scale of the exported variables. In this run, souHot.T_in uses K. Keep the exact channel name and unit together when exporting data to a historian. Read the component definition.
Data and source model