The recorded demand.port_a.m_flow channel spans 0.1505 to 0.4234 kg/s in this reference run. It starts at 0.287 and ends at 0.287. The first recorded maximum occurs at 2,000 seconds and the first minimum at 58,000 seconds.

The system being tested

The RWTH Aachen University E.ON Energy Research Center publishes the AixLib test named OpenLoopVarTSupplyDp. The source file places it under Fluid, District Heating Cooling, Demands. We used the 101 stored values for demand.port_a.m_flow over the interval 0 to 100,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name sourceIdeal (Source Ideal), demand (Var T Supply pressure difference), pipeSupply (Plug Flow Pipe), pipeReturn (Plug Flow Pipe). The source declares T_amb = 283.15. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel demand.senT_return.T starts at 333.15, ends at 327.468 and has a recorded range of 326.897 to 333.15 K. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Open-loop var t supply pressure difference. The simulated demand.port_a.m_flow channel runs from 0.1505 to 0.4234 kg/s over 100,000 seconds.
Open-loop var t supply pressure difference. The simulated demand.port_a.m_flow channel runs from 0.1505 to 0.4234 kg/s over 100,000 seconds. Figure by Industry Applied.

Reproduce the calculation

Integrating the signed rate over 100,000 seconds gives a net 28,697 kg. This estimate averages neighbouring stored rates and multiplies by their time separation. Reverse flow reduces the net total. If a process requires gross throughput, calculate forward and reverse transfers separately at the appropriate boundary.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

demand.port_a.m_flow (kg/s)

demand.senT_return.T (K)

0

0.2869678

333.15

2000

0.4234291

327.7137

20000

0.2869678

327.4683

29000

0.2026301

327.1502

30000

0.2869678

327.4684

40000

0.2869678

327.4683

58000

0.1505065

326.8968

60000

0.2869678

327.4684

80000

0.2869678

327.4684

100000

0.2869678

327.4683

What to check on site

Trace the transfer boundary between the central network and the local load. Identical terminal duty can coincide with different distribution losses and pump inputs. Use simultaneous primary and secondary measurements before allocating an energy difference to one side.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.