The recorded flo.att.TAir temperature spans -10.545 °C to 9.1439 °C in this simulation. That is a change of 19.689 K. The first saved maximum occurs at 134,784 s. The source trace and download retain absolute temperatures in kelvin.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named Unconditioned. The source file places it under Thermal Zones, Energy Plus 24 2 0, Small Office. We used the 101 stored values for flo.att.TAir over the interval 0 to 172,800 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name weaDat (Reader TMY3), weaBus (Bus), out (Outside), res (Pressure Drop). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

At 0 s, flo.att.TAir is 275.15 K and weaDat.weaBus.TDryBul is 260.95 K. Subtracting the second value from the first gives 14.2 K. This is their largest recorded absolute separation. A difference between an inlet and an outlet, or between a command and a response, need not be a measurement error.

Open-loop model of one floor. The simulated flo.att.TAir channel runs from 262.605 to 282.294 K over 172,800 seconds.
Open-loop model of one floor. The simulated flo.att.TAir channel runs from 262.605 to 282.294 K over 172,800 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 1,728 to 3,456 seconds. Subtracting 274.549 from 271.855 gives -2.694 K. Its location brackets the change within one saved interval of 1,728 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

flo.att.TAir (K)

weaDat.weaBus.TDryBul (K)

0

275.15

260.95

1728

274.5492

260.8676

3456

271.855

260.9343

25920

262.6048

262.5876

34560

268.5352

265.5892

69120

270.0163

271.0077

103680

267.2424

271.8394

134784

282.2939

274.2787

138240

281.137

272.7459

172800

272.0926

273.15

What to check on site

Identify the stored quantity and the boundary through which energy or mass enters. A layer temperature, outlet temperature and volume mean describe different states. Preserve initial inventory and the sequence of charge or discharge when repeating the case.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model