The recorded zon.TAir temperature spans 20 °C to 43.083 °C in this simulation. That is a change of 23.083 K. The first saved maximum occurs at 19,147,968 s. The source trace and download retain absolute temperatures in kelvin.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named OneZoneOneOutputVariableSummer. The source file places it under Thermal Zones, Energy Plus 24 2 0, Output Variable. We used the 101 stored values for zon.TAir over the interval 18,748,800 to 19,353,600 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 2 recorded variables. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

At 19,039,104 s, zon.TAir reads 308.226 K and equEle.y reads 500. Across the run, the second channel ranges from 0 to 500. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.

One zone with one output variable for a summer period. The simulated zon.TAir channel runs from 293.15 to 316.233 K over 604,800 seconds.
One zone with one output variable for a summer period. The simulated zon.TAir channel runs from 293.15 to 316.233 K over 604,800 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 19,033,056 to 19,039,104 seconds. Subtracting 303.594 from 308.226 gives 4.632 K. Its location brackets the change within one saved interval of 6,048 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

zon.TAir (K)

equEle.y (source units)

1.87488e+07

293.15

0

1.886976e+07

303.9046

500

1.899072e+07

307.0581

0

1.903306e+07

303.5943

0

1.90391e+07

308.2259

500

1.911168e+07

303.2127

0

1.914797e+07

316.2327

500

1.923264e+07

313.9899

500

1.93536e+07

305.6176

0

What to check on site

Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.