The recorded TEnePlu.y channel spans 285.524 to 296.107 source units in this reference run. It starts at 288.56 and ends at 288.55. The first recorded maximum occurs at 919,296 seconds and the first minimum at 889,056 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named OneZoneOutputVariable. The source file places it under Thermal Zones, Energy Plus 24 2 0, Output Variable. We used the 101 stored values for TEnePlu.y over the interval 864,000 to 950,400 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 1 recorded variables. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

The primary channel spends 34.7% of its saved checkpoints at or above 290.815 source units, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 289.945 source units. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.

One zone output variable. The simulated TEnePlu.y channel runs from 285.524 to 296.107 source units over 86,400 seconds.
One zone output variable. The simulated TEnePlu.y channel runs from 285.524 to 296.107 source units over 86,400 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 928,800 to 929,664 seconds. Subtracting 292.88 from 292.013 gives -0.8674 source units. Its location brackets the change within one saved interval of 864 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

TEnePlu.y (source units)

864000

288.5596

881280

286.4436

889056

285.5244

898560

288.7003

915840

295.3952

919296

296.1065

928800

292.8802

929664

292.0128

933120

291.0099

950400

288.5502

What to check on site

Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.