The recorded m_flow_data[1] channel spans -0.08356 to 0.08356 source units in this reference run. It starts at -0.08356 and ends at 0.08356. The first recorded maximum occurs at 500 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named OneWayFlow. The source file places it under Airflow, Multizone. We used the 101 stored values for m_flow_data[1] over the interval 0 to 500 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name bouA (Boundary p T), bouB (Boundary p T), ramp_min50_50pa (Ramp), PAmb (Constant). The source declares nTested = 8. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel m_flow_data[2] covers -0.06564 to 0.06564 source units. At 0 s, the primary value is -0.08356 and the companion is -0.06564. Their signed difference is -0.01792 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

One way flow. The simulated m_flow_data[1] channel runs from -0.08356 to 0.08356 source units over 500 seconds.
One way flow. The simulated m_flow_data[1] channel runs from -0.08356 to 0.08356 source units over 500 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 245 to 250 seconds. Subtracting -0.006572 from 0 gives 0.006572 source units. Its location brackets the change within one saved interval of 5 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

m_flow_data[1] (source units)

m_flow_data[2] (source units)

0

-0.0835631

-0.06564008

100

-0.05995327

-0.05084458

200

-0.02935513

-0.02935513

245

-0.006571796

-0.009282908

250

0

0

300

0.02935513

0.02935513

400

0.05995327

0.05084458

500

0.0835631

0.06564008

What to check on site

Identify the connected zones, pressure references and flow direction. Changing a door, leakage path or boundary condition can redistribute the same total flow between branches. A differential pressure alone cannot establish the air quantity reaching a zone.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.