The recorded flo.T temperature spans 20 °C to 23.726 °C in this simulation. That is a change of 3.7263 K. The first saved maximum occurs at 10,860,480 s. The source trace and download retain absolute temperatures in kelvin.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named OneZoneControlledFloorTemperature. The source file places it under Thermal Zones, Energy Plus 24 2 0, Zone Surface. We used the 101 stored values for flo.T over the interval 10,800,000 to 11,232,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name flo (Zone Surface), TSetRooHea (Constant), conHea (PID), TSetRooCoo (Constant). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

At 11,193,120 s, flo.T is 293.868 K and zon.TAir is 297.278 K. Subtracting the second value from the first gives -3.4094 K. This is their largest recorded absolute separation. A difference between an inlet and an outlet, or between a command and a response, need not be a measurement error.

One thermal zone with controlled floor temperature. The simulated flo.T channel runs from 293.15 to 296.876 K over 432,000 seconds.
One thermal zone with controlled floor temperature. The simulated flo.T channel runs from 293.15 to 296.876 K over 432,000 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 11,037,600 to 11,041,920 seconds. Subtracting 296.066 from 293.521 gives -2.545 K. Its location brackets the change within one saved interval of 4,320 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

flo.T (K)

zon.TAir (K)

1.08e+07

293.15

293.15

1.086048e+07

296.8763

296.8763

1.08864e+07

294.8716

292.9792

1.09728e+07

295.0205

293.1726

1.10376e+07

296.0656

296.0656

1.104192e+07

293.5206

293.5206

1.10592e+07

294.5348

293.062

1.11456e+07

294.3148

293.0765

1.1232e+07

294.1036

293.0684

What to check on site

Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.