The recorded zon.TAir temperature spans 20 °C to 23.961 °C in this simulation. That is a change of 3.9606 K. The first saved maximum occurs at 133,920 s. The source trace and download retain absolute temperatures in kelvin.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named OneZoneConstantFloorTemperature. The source file places it under Thermal Zones, Energy Plus 24 2 0, Zone Surface. We used the 101 stored values for zon.TAir over the interval 0 to 432,000 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name flo (Zone Surface), TFlo (Constant). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
At 30,240 s, zon.TAir is 294.543 K and zon.TRad is 296.154 K. Subtracting the second value from the first gives -1.6112 K. This is their largest recorded absolute separation. A difference between an inlet and an outlet, or between a command and a response, need not be a measurement error.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 371,520 to 375,840 seconds. Subtracting 294.467 from 295.463 gives 0.996 K. Its location brackets the change within one saved interval of 4,320 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | zon.TAir (K) | zon.TRad (K) |
|---|---|---|
0 | 293.15 | 292.8582 |
86400 | 294.9046 | 296.135 |
133920 | 297.1106 | 297.257 |
172800 | 295.3722 | 296.4218 |
259200 | 295.0789 | 296.2376 |
345600 | 294.6394 | 295.9794 |
371520 | 294.4671 | 295.5645 |
375840 | 295.4632 | 296.3018 |
432000 | 294.3819 | 295.8104 |
What to check on site
Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Units in the source model
The component declarations identify the scale of the exported variables. In this run, zon.TRad uses K. Keep the exact channel name and unit together when exporting data to a historian. Read the component definition.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.