The published unitDelay1.y signal spans -0.588 to 0.951 source signal units in the reference run. It starts at 0 and finishes at -0.588. The signed change between those endpoint samples is -0.588 source signal units.
What the reference test measures
The Buildings model named UnitDelay comes from Lawrence Berkeley National Laboratory. The saved result covers simulation time 0 to 1 seconds. Industry Applied extracted 101 checkpoints for unitDelay1.y and kept the original signed values. The regular output spacing is 0.01 seconds. The solver may take different internal steps.
The model definition identifies unitDelay1 (Unit Delay), ramp1 (Ramp), sin1 (Sin). These component names let a reader trace the plotted tags to their owning blocks before reproducing the result.
Settings to preserve when repeating the experiment
The published test declares unitDelay1.samplePeriod = 0.2, ramp1.duration = 1, ramp1.offset = 0. Those numbers use the units and component definitions in the linked model. Start with the declared configuration when reproducing the reference result, then vary one setting at a time. Changing the input waveform and the component response in the same comparison makes it difficult to identify the source of a difference.
Reading the two channels
At 0.75 seconds, unitDelay1.y is 0.588 and unitDelay1.u is -1. Subtracting the second channel from the first gives +1.588 source signal units, the largest absolute separation on their common saved grid. The channels have distinct roles in the model, so this difference describes the two traces and is not a calibrated instrument error.

Reproducing the largest recorded change
Between the stored points at 0.8 and 0.81 seconds, unitDelay1.y changes from 0.588 to -0.588. Subtracting the earlier reading gives -1.176 source signal units. This interval contains the largest absolute point-to-point change in the saved primary channel. A faster excursion followed by recovery could fit entirely between the two records.
The extrema in the table and figure are extrema of the stored series. A solver’s internal peak, a field logger’s alarm value and a maximum derived from this export can differ. Preserve the sampling settings when comparing results.
Worked data
Simulation time (s) | unitDelay1.y (signal units) | unitDelay1.u (signal units) |
|---|---|---|
0 | 0 | 0 |
0.25 | 0 | 1 |
0.41 | 0.9510565 | 0.5358268 |
0.5 | 0.9510565 | 5.358979e-08 |
0.75 | 0.5877853 | -1 |
0.8 | 0.5877853 | -0.9510566 |
0.81 | -0.5877852 | -0.9297765 |
1 | -0.5877852 | -1.071796e-07 |
Applying the result to an operating site
A delay of one sample becomes a time delay only after the sample period is known. Record that period when exporting the trend. Compare values by sample index before interpreting the shifted output as physical transport lag.
For an Australian monitoring project, write the intended sample interval, timestamp convention, tag units and missed-update policy into the acceptance record. Re-run this comparison on the installed signal path and retain the raw export so a later dashboard change can be checked against the same baseline.
Model and data sources
Model definition. Original numerical reference series. Simulation and plotting script. Source project. Download the worked checkpoints as CSV.
Cover photograph by ed br, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.