The recorded bouB.T_in channel spans 273.15 to 308.15 source units in this reference run. It starts at 273.15 and ends at 308.15. The first recorded maximum occurs at 25,344 seconds and the first minimum at 0 seconds.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named OpenDoorTemperature. The source file places it under Airflow, Multizone. We used the 101 stored values for bouB.T_in over the interval 0 to 28,800 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name doo (Door Open), bouA (Boundary p T), bouB (Boundary p T), dooDis (Door Discretized Open). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel doo.vAB covers 0 to 0.2568 source units. At 25,344 s, the primary value is 308.15 and the companion is 0.2224. Their signed difference is 307.928 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 3,456 to 3,744 seconds. Subtracting 273.15 from 278.15 gives 5 source units. Its location brackets the change within one saved interval of 288 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | bouB.T_in (source units) | doo.vAB (source units) |
|---|---|---|
0 | 273.15 | 0.256822 |
3456 | 273.15 | 0.256822 |
3744 | 278.15 | 0.2224143 |
5760 | 278.15 | 0.2224143 |
11520 | 288.15 | 0.128411 |
17280 | 293.15 | 0 |
23040 | 303.15 | 0.1816005 |
25344 | 308.15 | 0.2224143 |
28800 | 308.15 | 0.2224143 |
What to check on site
Identify the connected zones, pressure references and flow direction. Changing a door, leakage path or boundary condition can redistribute the same total flow between branches. A differential pressure alone cannot establish the air quantity reaching a zone.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.