The recorded doo.port_a2.p channel spans 101,305 to 101,340 Pa in this reference run. It starts at 101,305 and ends at 101,340. The first recorded maximum occurs at 25,344 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named OpenDoorPressure. The source file places it under Airflow, Multizone. We used the 101 stored values for doo.port_a2.p over the interval 0 to 28,800 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name doo (Door Open), bouA (Boundary p T), bouB (Boundary p T), dooDis (Door Discretized Open). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel doo.vAB starts at 3.753, ends at 0 and has a recorded range of 0 to 3.753 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

One open door and only pressure-driven flow. The simulated doo.port_a2.p channel runs from 101,305 to 101,340 Pa over 28,800 seconds.
One open door and only pressure-driven flow. The simulated doo.port_a2.p channel runs from 101,305 to 101,340 Pa over 28,800 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 3,456 to 3,744 seconds. Subtracting 101,305 from 101,310 gives 5 Pa. Its location brackets the change within one saved interval of 288 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

doo.port_a2.p (Pa)

doo.vAB (source units)

0

101305

3.752777

3456

101305

3.752777

3744

101310

3.25

5760

101310

3.25

11520

101320

1.876388

17280

101325

0

23040

101335

0

25344

101340

0

28800

101340

0

What to check on site

Identify the connected zones, pressure references and flow direction. Changing a door, leakage path or boundary condition can redistribute the same total flow between branches. A differential pressure alone cannot establish the air quantity reaching a zone.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.