The recorded zon.TAir temperature spans 9.3827 °C to 20 °C in this simulation. That is a change of 10.617 K. The first saved maximum occurs at 0 s. The source trace and download retain absolute temperatures in kelvin.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named LightsControl. The source file places it under Thermal Zones, Energy Plus 24 2 0, Single Family House. We used the 101 stored values for zon.TAir over the interval 0 to 172,800 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name actLig (Actuator), ligPow (Output Variable), sunRiseSet (Sun Rise Set), mod1 (Modulo). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

At 1,728 s, zon.TAir reads 289.782 K and PLig.y reads 0. Across the run, the second channel ranges from 0 to 1,000. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.

One actuator that controls the lights in energy plus. The simulated zon.TAir channel runs from 282.533 to 293.15 K over 172,800 seconds.
One actuator that controls the lights in energy plus. The simulated zon.TAir channel runs from 282.533 to 293.15 K over 172,800 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 1,728 seconds. Subtracting 293.15 from 289.782 gives -3.368 K. Its location brackets the change within one saved interval of 1,728 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

zon.TAir (K)

PLig.y (source units)

0

293.15

0

1728

289.7816

0

34560

286.8332

0

69120

286.7699

1000

103680

283.1782

0

110592

282.5327

0

138240

285.6986

0

172800

283.3349

0

What to check on site

Distinguish the component characteristic from the installed system response. Record the pressure or temperature on both sides as applicable, the direction of flow and the actuator command. Compare a change at constant demand with one caused by a different load.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.