The recorded beaCooHea.heaToRoo.Q_flow channel spans -1,092 to 2,832 W in this reference run. It starts at -1,092 and ends at 2,832. The first recorded maximum occurs at 3,050 seconds and the first minimum at 0 seconds.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named NumberOfBeams. The source file places it under Fluid, Heat Exchangers, Active Beams. We used the 101 stored values for beaCooHea.heaToRoo.Q_flow over the interval 0 to 5,000 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name sin_1 (Boundary p T), souAir (Mass Flow Source T), sou_1 (Boundary p T), pumHotWat (Flow Controlled m flow). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel beaCooHea10.heaToRoo.Q_flow covers -10,920 to 28,320 W. At 3,050 s, the primary value is 2,832 and the companion is 28,320. Their signed difference is -25,488 W, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Reproduce the calculation
Integrating the signed beaCooHea.heaToRoo.Q_flow samples by the trapezoidal rule gives 0.9394 kWh over 5,000 seconds. For each pair, average the two powers in watts and multiply by the interval in seconds. Sum the watt-seconds and divide by 3,600,000. This value refers to the selected simulation connector and should be assigned to a physical load only after confirming the boundary and sign.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | beaCooHea.heaToRoo.Q_flow (W) | beaCooHea10.heaToRoo.Q_flow (W) |
|---|---|---|
0 | -1092 | -10920 |
1000 | -1092 | -10920 |
2000 | -1092 | -10920 |
3000 | 0 | 0 |
3050 | 2832 | 28320 |
4000 | 2832 | 28320 |
5000 | 2832 | 28320 |
What to check on site
Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.