The norQSta.SOC trace ranges from 0 to 1 across 101 saved checkpoints. It begins at 1 and finishes at 1 after 7,200 s of test time. The source identifies the channel scale as dimensionless. Its first saved maximum occurs at 0 s.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named NormalizedHeatFlowRate. The source file places it under Fluid, Storage, Ice. We used the 101 stored values for norQSta.SOC over the interval 0 to 7,200 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name fra (Cosine), norQSta (Normalized Heat Flow Rate), lmtd (Step), greThr (Greater Threshold). The source declares dt = 3600. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

At 1,800 s, norQSta.SOC reads 0.5 and norQSta.canMelt reads 1. Across the run, the second channel ranges from 0 to 1. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.

Normalized heat flow rate. The simulated norQSta.SOC channel runs from 0 to 1 fraction over 7,200 seconds.
Normalized heat flow rate. The simulated norQSta.SOC channel runs from 0 to 1 fraction over 7,200 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 1,728 to 1,800 seconds. Subtracting 0.5314 from 0.5 gives -0.0314 fraction. Its location brackets the change within one saved interval of 72 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

norQSta.SOC (dimensionless)

norQSta.canMelt (logical state)

0

1

1

1440

0.6545085

1

1728

0.5313953

1

1800

0.5

1

2880

0.09549151

1

3600

0

1

4320

0.09549151

0

5760

0.6545085

0

7200

1

0

What to check on site

Identify the stored quantity and the boundary through which energy or mass enters. A layer temperature, outlet temperature and volume mean describe different states. Preserve initial inventory and the sequence of charge or discharge when repeating the case.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Units in the source model

The component declarations identify the scale of the exported variables. In this run, norQSta.canMelt uses logical state. Keep the exact channel name and unit together when exporting data to a historian. Read the component definition.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.