The recorded T_leg0.port_a.m_flow channel spans 0.001 to 0.999 kg/s in this reference run. It starts at 0.001 and ends at 0.999. The first recorded maximum occurs at 100 seconds and the first minimum at 0 seconds.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named ThreeWayValveSwitch. The source file places it under Fluid, Actuators, Valves, Simplified. We used the 101 stored values for T_leg0.port_a.m_flow over the interval 0 to 10,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name pulse (Pulse). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel T_leg1.port_a.m_flow covers 0.001 to 0.999 kg/s. At 0 s, the primary value is 0.001 and the companion is 0.999. Their signed difference is -0.998 kg/s, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

New component three-way valve switch. The simulated T_leg0.port_a.m_flow channel runs from 0.001 to 0.999 kg/s over 10,000 seconds.
New component three-way valve switch. The simulated T_leg0.port_a.m_flow channel runs from 0.001 to 0.999 kg/s over 10,000 seconds. Figure by Industry Applied.

Reproduce the calculation

Integrating the signed rate over 10,000 seconds gives a net 9,940 kg. This estimate averages neighbouring stored rates and multiplies by their time separation. Reverse flow reduces the net total. If a process requires gross throughput, calculate forward and reverse transfers separately at the appropriate boundary.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

T_leg0.port_a.m_flow (kg/s)

T_leg1.port_a.m_flow (kg/s)

0

0.001

0.999

100

0.999

0.001

2000

0.999

0.001

4000

0.999

0.001

6000

0.999

0.001

8000

0.999

0.001

10000

0.999

0.001

What to check on site

Distinguish the component characteristic from the installed system response. Record the pressure or temperature on both sides as applicable, the direction of flow and the actuator command. Compare a change at constant demand with one caused by a different load.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.