The recorded pmpNorth.m_flow channel spans -1.06e-05 to 6.885 kg/s in this reference run. It starts at 0 and ends at 0. The first recorded maximum occurs at 330 seconds and the first minimum at 540 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named Simplified3. The source file places it under Fluid, Flow System. We used the 101 stored values for pmpNorth.m_flow over the interval 0 to 1,000 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 2 recorded variables. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

The companion channel pmpSouth.m_flow covers -9.45e-06 to 6.162 kg/s. At 330 s, the primary value is 6.885 and the companion is 6.162. Their signed difference is 0.7226 kg/s, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Neglecting pressure drop in splitters. The simulated pmpNorth.m_flow channel runs from -1.06e-05 to 6.885 kg/s over 1,000 seconds.
Neglecting pressure drop in splitters. The simulated pmpNorth.m_flow channel runs from -1.06e-05 to 6.885 kg/s over 1,000 seconds. Figure by Industry Applied.

Reproduce the calculation

Integrating the signed rate over 1,000 seconds gives a net 3,098 kg. This estimate averages neighbouring stored rates and multiplies by their time separation. Reverse flow reduces the net total. If a process requires gross throughput, calculate forward and reverse transfers separately at the appropriate boundary.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

pmpNorth.m_flow (kg/s)

pmpSouth.m_flow (kg/s)

0

0

0

10

2.592565

2.351489

200

5.984308

5.451402

330

6.884717

6.162096

400

6.442147

5.813002

540

-1.063026e-05

-9.445994e-06

600

6.112928e-12

5.676472e-12

800

0

0

1000

0

0

What to check on site

Mark the measurement points on a hydraulic schematic and identify whether the controller holds flow or differential pressure. Record pump command and delivered duty together. A site comparison needs the same branch state, including bypasses and closed valves.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.