The hANatCyl.hA trace ranges from 0.077776 W/K to 15.687 W/K across 101 saved checkpoints. It begins at 0.08016 W/K and finishes at 0.077776 W/K after 250 s of test time. The source identifies the channel scale as W/K. Its first saved maximum occurs at 100 s.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named HANaturalCylinder. The source file places it under Fluid, Heat Exchangers. We used the 101 stored values for hANatCyl.hA over the interval 0 to 250 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name hANatCyl (HA Natural Cylinder), TSur (Ramp), TFlu (Ramp). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The primary channel spends 87.1% of its saved checkpoints at or above 7.882 source units, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 12.551 source units. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.

Natural convection outside of a coil. The simulated hANatCyl.hA channel runs from 0.07778 to 15.687 source units over 250 seconds.
Natural convection outside of a coil. The simulated hANatCyl.hA channel runs from 0.07778 to 15.687 source units over 250 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 247.5 to 250 seconds. Subtracting 5.857 from 0.07778 gives -5.779 source units. Its location brackets the change within one saved interval of 2.5 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

hANatCyl.hA (W/K)

0

0.08016003

50

11.07557

100

15.68711

150

15.68711

200

13.87592

247.5

5.856976

250

0.07777636

What to check on site

Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Units in the source model

The component declarations identify the scale of the exported variables. In this run, hANatCyl.hA uses W/K. Keep the exact channel name and unit together when exporting data to a historian. Read the component definition.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.