The recorded ach channel spans 3.46e-08 to 3 source units in this reference run. It starts at 3.46e-08 and ends at 3. The first recorded maximum occurs at 2.01 seconds and the first minimum at 0 seconds.
The system being tested
The KU Leuven IDEAS project publishes the IDEAS test named n50Test2TwoPort. The source file places it under Buildings, Tests. We used the 101 stored values for ach over the interval 0 to 3 seconds. This is a simulated test with specified inputs and boundaries.
The reference file contains 2 recorded variables. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.
Compare the recorded channels
The companion channel ach1 covers 3.37e-08 to 2 source units. At 2.01 s, the primary value is 3 and the companion is 2. Their signed difference is 1 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 0.99 to 1.02 seconds. Subtracting 3.46e-08 from 0.2359 gives 0.2359 source units. Its location brackets the change within one saved interval of 0.03 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | ach (source units) | ach1 (source units) |
|---|---|---|
0 | 3.460399e-08 | 3.460399e-08 |
0.6 | 3.460417e-08 | 3.408671e-08 |
0.99 | 3.460429e-08 | 3.374705e-08 |
1.02 | 0.2359343 | 0.1572847 |
1.2 | 1.053879 | 0.7025643 |
1.8 | 2.594955 | 1.729917 |
2.01 | 3 | 1.999938 |
2.4 | 3 | 1.999938 |
3 | 3 | 1.999938 |
What to check on site
Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.