The ach trace ranges from 2.392e-09 to 3 across 101 saved checkpoints. It begins at 2.392e-09 and finishes at 3 after 3 s of test time. The reference export does not state a verified engineering unit for this value. Use its native scale when comparing another run of the same model.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named n50Test. The source file places it under Buildings, Tests. We used the 101 stored values for ach over the interval 0 to 3 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name weaDatBus1 (Bus). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The primary channel spends 55.4% of its saved checkpoints at or above 1.5 source units, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 1.606 source units. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.

N50 consistency check for one port. The simulated ach channel runs from 2.39e-09 to 3 source units over 3 seconds.
N50 consistency check for one port. The simulated ach channel runs from 2.39e-09 to 3 source units over 3 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0.99 to 1.02 seconds. Subtracting 2.39e-09 from 0.2359 gives 0.2359 source units. Its location brackets the change within one saved interval of 0.03 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

ach (source units)

0

2.391828e-09

0.6

2.391828e-09

0.99

2.391828e-09

1.02

0.2359343

1.2

1.053879

1.8

2.594955

2.01

3

2.4

3

3

3

What to check on site

Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.