The recorded multizone.TAir[1] channel spans 290.329 to 296.355 source units in this reference run. It starts at 293.15 and ends at 292.61. The first recorded maximum occurs at 15,517,440 seconds and the first minimum at 14,791,680 seconds.
The system being tested
The RWTH Aachen University E.ON Energy Research Center publishes the AixLib test named MultizonePartlyCooled. The source file places it under Thermal Zones, Reduced Order. We used the 101 stored values for multizone.TAir[1] over the interval 14,688,000 to 15,552,000 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name multizone (Multizone), weaDat (Reader TMY3), weaBus (Bus), replicatorTemperatureVentilation (Replicator). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel multizone.TAir[2] covers 289.608 to 295.756 source units. At 15,310,080 s, the primary value is 291.126 and the companion is 290.158. Their signed difference is 0.9678 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.
![Multizone partly cooled. The simulated multizone.TAir[1] channel runs from 290.329 to 296.355 source units over 864,000 seconds.](https://static.wixstatic.com/media/21e41b_6d9295230a3545f68cb9acc5ada73b8c~mv2.png/v1/fill/w_616,h_345,al_c,q_85,enc_auto/21e41b_6d9295230a3545f68cb9acc5ada73b8c~mv2.png)
Reproduce the calculation
The largest absolute change between consecutive stored points appears from 14,688,000 to 14,696,640 seconds. Subtracting 293.15 from 290.542 gives -2.608 source units. Its location brackets the change within one saved interval of 8,640 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | multizone.TAir[1] (source units) | multizone.TAir[2] (source units) |
|---|---|---|
1.4688e+07 | 293.15 | 293.15 |
1.469664e+07 | 290.5423 | 290.0311 |
1.479168e+07 | 290.3289 | 289.669 |
1.48608e+07 | 290.6415 | 289.938 |
1.50336e+07 | 291.3443 | 290.5614 |
1.52064e+07 | 291.3527 | 290.4716 |
1.53792e+07 | 291.2672 | 290.3582 |
1.551744e+07 | 296.3546 | 295.7561 |
1.5552e+07 | 292.6103 | 291.7671 |
What to check on site
Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.