The recorded multizone.TAir[1] temperature spans 14.794 °C to 23.868 °C in this simulation. That is a change of 9.0732 K. The first saved maximum occurs at 19,236,960 s. The source trace and download retain absolute temperatures in kelvin.

The system being tested

The RWTH Aachen University E.ON Energy Research Center publishes the AixLib test named MultizoneMoistAirCO2. The source file places it under Thermal Zones, Reduced Order. We used the 101 stored values for multizone.TAir[1] over the interval 0 to 31,536,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name multizone (Multizone), weaDat (Reader TMY3), tableInternalGains (Combi Time Table), sine (Sine). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

At 19,552,320 s, multizone.TAir[1] reads 293.217 K and multizone.CO2Con[1] reads 402.666. Across the run, the second channel ranges from 0 to 631.561. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 19,236,960 to 19,552,320 seconds. Subtracting 297.018 from 293.217 gives -3.8 source units. Its location brackets the change within one saved interval of 315,360 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

multizone.TAir[1] (K)

multizone.CO2Con[1] (source units)

0

293.15

0

630720

287.9444

403.323

6307200

291.4458

402.6781

1.26144e+07

292.1

402.6743

1.89216e+07

293.5604

402.6699

1.923696e+07

297.0176

520.4432

1.955232e+07

293.2174

402.666

2.52288e+07

292.9306

402.673

3.1536e+07

289.179

405.0152

What to check on site

Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Units in the source model

The component declarations identify the scale of the exported variables. In this run, multizone.TAir[1] uses K. Keep the exact channel name and unit together when exporting data to a historian. Read the component definition.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.