The recorded multizone.TAir[1] channel spans 272.841 to 285.621 source units in this reference run. It starts at 277.15 and ends at 279.203. The first recorded maximum occurs at 3,245,760 seconds and the first minimum at 3,124,800 seconds.
The system being tested
The RWTH Aachen University E.ON Energy Research Center publishes the AixLib test named MultizoneInterzonalsFixedHeater. The source file places it under Thermal Zones, Reduced Order. We used the 101 stored values for multizone.TAir[1] over the interval 2,797,200 to 3,301,200 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name weaDat (Reader TMY3), tableInternalGains (Combi Time Table), tableAHU (Combi Time Table), tableTSet (Combi Time Table). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel multizone.TAir[2] covers 276.899 to 282.496 source units. At 3,160,080 s, the primary value is 283.976 and the companion is 279.21. Their signed difference is 4.765 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.
![Multizone interzonals fixed heater. The simulated multizone.TAir[1] channel runs from 272.841 to 285.621 source units over 504,000 seconds.](https://static.wixstatic.com/media/21e41b_7bf0e9fbf031469eb0c38b809af3c507~mv2.png/v1/fill/w_616,h_345,al_c,q_85,enc_auto/21e41b_7bf0e9fbf031469eb0c38b809af3c507~mv2.png)
Reproduce the calculation
The largest absolute change between consecutive stored points appears from 3,155,040 to 3,160,080 seconds. Subtracting 280.528 from 283.976 gives 3.448 source units. Its location brackets the change within one saved interval of 5,040 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | multizone.TAir[1] (source units) | multizone.TAir[2] (source units) |
|---|---|---|
2797200 | 277.15 | 277.15 |
2898000 | 277.0886 | 277.1174 |
2998800 | 276.9421 | 277.0945 |
3099600 | 277.9996 | 277.583 |
3124800 | 272.8411 | 277.1174 |
3155040 | 280.528 | 278.4943 |
3160080 | 283.9756 | 279.2102 |
3200400 | 279.4026 | 280.0423 |
3245760 | 285.6205 | 281.8828 |
3301200 | 279.2029 | 282.472 |
What to check on site
Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. [Download the worked checkpoints in CSV format](https://www.industryapplied.com/field-data/multizone-interzonal exchange with-fixed-heater-output-reference-measurements.csv).