The recorded VAV_1.bus.fanSup.V_flow channel spans 0 to 0.4559 m³/s in this reference run. It starts at 0 and ends at 0.4181. The first recorded maximum occurs at 1,600 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named VAVMultiZone. The source file places it under Templates, Air Handlers Fans. We used the 101 stored values for VAV_1.bus.fanSup.V_flow over the interval 0 to 10,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name VAV_1 (variable air volume Multi Zone), bouOut (Boundary p T), bouBui (Boundary p T), pBui (Pressure). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel VAV_1.bus.TAirMix starts at 293.15, ends at 293.332 and has a recorded range of 293.15 to 293.4 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Multiple-zone variable air volume. The simulated VAV_1.bus.fanSup.V_flow channel runs from 0 to 0.4559 m³/s over 10,000 seconds.
Multiple-zone variable air volume. The simulated VAV_1.bus.fanSup.V_flow channel runs from 0 to 0.4559 m³/s over 10,000 seconds. Figure by Industry Applied.

Reproduce the calculation

Integrating the signed rate over 10,000 seconds gives a net 4,101 m³. This estimate averages neighbouring stored rates and multiplies by their time separation. Reverse flow reduces the net total. If a process requires gross throughput, calculate forward and reverse transfers separately at the appropriate boundary.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

VAV_1.bus.fanSup.V_flow (m³/s)

VAV_1.bus.TAirMix (source units)

0

0

293.15

100

0.1024977

293.2301

1600

0.4558625

293.3121

2000

0.4496375

293.3148

4000

0.4315904

293.3241

6000

0.4234863

293.3286

8000

0.4197759

293.3308

10000

0.4180647

293.3318

What to check on site

Separate a calculated setpoint from the damper or fan command and from the measured service delivered. Trend the active operating mode, request, actual flow and zone condition on one clock. A sequence can change state correctly while the terminal fails to reach duty.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.