The published movAve1.y signal spans -0.18 to 0.718 source signal units in the reference run. It starts at 0 and finishes at 0.127. The signed change between those endpoint samples is +0.127 source signal units.

What the reference test measures

The Buildings model named MovingAverage comes from Lawrence Berkeley National Laboratory. The saved result covers simulation time 0 to 900 seconds. Industry Applied extracted 101 checkpoints for movAve1.y and kept the original signed values. The regular output spacing is 9 seconds. The solver may take different internal steps.

The model definition identifies sinInpNoDel (Sin), movAve1 (Moving Average), movAve2 (Moving Average). These component names let a reader trace the plotted tags to their owning blocks before reproducing the result.

Settings to preserve when repeating the experiment

The published test declares sinInp50sDel.startTime = 50, sinInp100sDel.startTime = 100. Those numbers use the units and component definitions in the linked model. Start with the declared configuration when reproducing the reference result, then vary one setting at a time. Changing the input waveform and the component response in the same comparison makes it difficult to identify the source of a difference.

Reading the two channels

At 54 seconds, movAve1.y is 0.343 and sinInpNoDel.y is -0.891. Subtracting the second channel from the first gives +1.234 source signal units, the largest absolute separation on their common saved grid. The channels have distinct roles in the model, so this difference describes the two traces and is not a calibrated instrument error.

Moving-average output. In the simulated MovingAverage case, movAve1.y ranges from -0.18 to 0.718 source signal units over 900 seconds.
Moving-average output. In the simulated MovingAverage case, movAve1.y ranges from -0.18 to 0.718 source signal units over 900 seconds. Figure by Industry Applied.

Reproducing the largest recorded change

Between the stored points at 0 and 9 seconds, movAve1.y changes from 0 to 0.339. Subtracting the earlier reading gives +0.339 source signal units. This interval contains the largest absolute point-to-point change in the saved primary channel. A faster excursion followed by recovery could fit entirely between the two records.

The extrema in the table and figure are extrema of the stored series. A solver’s internal peak, a field logger’s alarm value and a maximum derived from this export can differ. Preserve the sampling settings when comparing results.

Worked data

Simulation time (s)

movAve1.y (signal units)

sinInpNoDel.y (signal units)

0

0

0

9

0.338955

0.649448

27

0.7179646

0.8526402

225

-0.1660671

-0.9238795

450

0.0002230705

-0.7071068

630

-0.1798424

-0.7071068

675

0.1662381

0.3826834

900

0.12701

1

Applying the result to an operating site

Keep the underlying samples as well as the smoothed trend. Averages can suppress a short peak and change the apparent time of a crossing. A monitoring specification should state the window and whether the value is stamped at the end or centre.

For an Australian monitoring project, write the intended sample interval, timestamp convention, tag units and missed-update policy into the acceptance record. Re-run this comparison on the installed signal path and retain the raw export so a later dashboard change can be checked against the same baseline.