The recorded pump_y.m_flow channel spans 0 to 1.601 kg/s in this reference run. It starts at 0 and ends at 1.601. The first recorded maximum occurs at 1 seconds and the first minimum at 0 seconds.

The system being tested

The RWTH Aachen University E.ON Energy Research Center publishes the AixLib test named MoverContinuous. The source file places it under Fluid, Movers. We used the 101 stored values for pump_y.m_flow over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name ramp (Ramp), gai_m_flow (Gain), gai_dp (Gain). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel pump_dp.m_flow covers 0 to 2 kg/s. At 0.39 s, the primary value is 0.6242 and the companion is 1.249. Their signed difference is -0.6248 kg/s, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Movers using a real input for setting the stage. The simulated pump_y.m_flow channel runs from 0 to 1.601 kg/s over 1 seconds.
Movers using a real input for setting the stage. The simulated pump_y.m_flow channel runs from 0 to 1.601 kg/s over 1 seconds. Figure by Industry Applied.

Reproduce the calculation

Integrating the signed rate over 1 seconds gives a net 0.8008 kg. This estimate averages neighbouring stored rates and multiplies by their time separation. Reverse flow reduces the net total. If a process requires gross throughput, calculate forward and reverse transfers separately at the appropriate boundary.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

pump_y.m_flow (kg/s)

pump_dp.m_flow (kg/s)

0

0

0

0.01

0.04017464

0.09328862

0.2

0.3200159

0.8944272

0.4

0.6402549

1.264911

0.6

0.9604939

1.549193

0.8

1.280733

1.788854

1

1.600972

2

What to check on site

Mark the measurement points on a hydraulic schematic and identify whether the controller holds flow or differential pressure. Record pump command and delivered duty together. A site comparison needs the same branch state, including bypasses and closed valves.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.