The lowest observed group mean is 7.995 for average ambient temperature (degrees f group 70.7 to 76.7. The highest is 11.447 for group 28.1 to 35.3, a difference of 3.452 on the source response scale. Across all 25 numeric records the response median is 9.14.
What was measured
The DRAPER8 data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as pounds of stema used per month. It preserves the source scale and its sign. The file contains 2 numeric fields per accepted row.
Spread across the original readings
The two endpoint groups have 6 and 7 observations. Their medians are 8.16 and 11.13, respectively. The figure groups the original entries by the recorded average ambient temperature (degrees f value. Where there are more than eight distinct settings, it groups them at empirical quartiles and labels each band with its observed endpoints.

One row you can check
To check a real observation, take numeric row 10 after the header. Its response is 9.14. The overall arithmetic mean is 9.424, so this observation is -0.284 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 2.54, calculated by subtracting 8.4 from 10.94.
The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.
Worked data
average ambient temperature (degrees f group | Observations | Mean response | Median response | Minimum response | Maximum response |
|---|---|---|---|---|---|
28.1 to 35.3 | 7 | 11.44714 | 11.13 | 10.36 | 12.51 |
39.1 to 57.5 | 6 | 9.388333 | 9.355 | 8.24 | 10.94 |
58.1 to 70 | 6 | 8.528333 | 8.435 | 6.83 | 10.09 |
70.7 to 76.7 | 6 | 7.995 | 8.16 | 6.36 | 8.88 |
Implications for an industrial comparison
Keep the measurement location, observation interval and averaging rule beside the figure. An extreme in a short record cannot supply a design return period. When comparing installations or environmental records, check whether both instruments observed the same temporal and spatial scale.
Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.
Source file and worked data
The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.