The vol.p trace ranges from 101,325 Pa to 202,650 Pa across 101 saved checkpoints. It begins at 101,325 Pa and finishes at 202,650 Pa after 120 s of test time. The source identifies the channel scale as Pa. Its first saved maximum occurs at 120 s.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named MassAccumulation. The source file places it under Fluid, Mixing Volumes. We used the 101 stored values for vol.p over the interval 0 to 120 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name vol (Mixing Volume), sou (Mass Flow Source T). The source declares X_w = 0.01, C = 1e-3, m_flow = 0.01. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

At 69.6 s, vol.p reads 160,093.5 Pa and mAir reads 1.896 kg. Across the run, the second channel ranges from 1.2 kg to 2.4 kg. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.

Mixing volumes conservation equation. The simulated vol.p channel runs from 101,325 to 202,650 Pa over 120 seconds.
Mixing volumes conservation equation. The simulated vol.p channel runs from 101,325 to 202,650 Pa over 120 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 68.4 to 69.6 seconds. Subtracting 159,080 from 160,094 gives 1,013 Pa. Its location brackets the change within one saved interval of 1.2 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

vol.p (Pa)

mAir (kg)

0

101325

1.2

24

121590

1.44

48

141855

1.68

68.4

159080.2

1.884

69.6

160093.5

1.896

72

162120

1.92

96

182385

2.16

120

202650

2.4

What to check on site

Distinguish the component characteristic from the installed system response. Record the pressure or temperature on both sides as applicable, the direction of flow and the actuator command. Compare a change at constant demand with one caused by a different load.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Units in the source model

The component declarations identify the scale of the exported variables. In this run, mAir uses kg. Keep the exact channel name and unit together when exporting data to a historian. Read the component definition.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.