The vol1.T trace covers 10.904 to 21.704 °C, a temperature span of 10.799 K. The first recorded maximum occurs at 18 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named MixingVolumeMoistAir. The source file places it under Fluid, Mixing Volumes. We used the 101 stored values for vol1.T over the interval 0 to 600 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name vol1 (Mixing Volume Moist Air), TSen (Temperature Sensor), XSet (Constant), TSet (Constant). The source declares m_flow_nominal = 0.001. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel vol1.X_w starts at 0.01, ends at 0.005 and has a recorded range of 0.004973 to 0.01 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Mixing volume with moist air input. The simulated vol1.T channel runs from 284.054 to 294.854 K over 600 seconds.
Mixing volume with moist air input. The simulated vol1.T channel runs from 284.054 to 294.854 K over 600 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 6 to 12 seconds. Subtracting 284.054 from 294.775 gives 10.721 K. Its location brackets the change within one saved interval of 6 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

vol1.T (K)

vol1.X_w (source units)

0

293.15

0.01

6

284.0542

0.005273618

12

294.7752

0.00497348

18

294.8536

0.004997458

120

293.1494

0.005

240

293.15

0.005

360

293.15

0.005

480

293.15

0.005

600

293.15

0.005

What to check on site

Distinguish the component characteristic from the installed system response. Record the pressure or temperature on both sides as applicable, the direction of flow and the actuator command. Compare a change at constant demand with one caused by a different load.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.