The volT.heatPort.Q_flow series gives a net -1.174e-15 kWh over 2 s when the saved power samples are joined by straight lines. The highest recorded power is 4.184 W. The sign follows the model’s measurement boundary. It matters when a connector can exchange energy in either direction.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named MixingVolumeZeroFlow. The source file places it under Fluid, Mixing Volumes. We used the 101 stored values for volT.heatPort.Q_flow over the interval 0 to 2 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name volNonLinSys (Mixing Volume), sou2 (Mass Flow Source T), sin (Boundary p T), ramp_m_flow (Ramp). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
At 0 s, volT.heatPort.Q_flow is 4.184 W and volLinSys.heatPort.Q_flow is 0.8071 W. Subtracting the second value from the first gives 3.3769 W. This is their largest recorded absolute separation. A difference between an inlet and an outlet, or between a command and a response, need not be a measurement error.

Reproduce the calculation
Integrating the signed volT.heatPort.Q_flow samples by the trapezoidal rule gives 0 kWh over 2 seconds. For each pair, average the two powers in watts and multiply by the interval in seconds. Sum the watt-seconds and divide by 3,600,000. This value refers to the selected simulation connector and should be assigned to a physical load only after confirming the boundary and sign.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | volT.heatPort.Q_flow (W) | volLinSys.heatPort.Q_flow (W) |
|---|---|---|
0 | 4.184 | 0.8070987 |
0.18 | 1.460798 | 0.3296857 |
0.2 | 1.034342 | 0.2379329 |
0.4 | -2.030956 | -0.5785541 |
0.46 | -2.188378 | -0.6714134 |
0.8 | 0.2585854 | 0.1407804 |
1.2 | 0 | 0 |
1.6 | 0 | 0 |
2 | 0 | 0 |
What to check on site
Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.