The senTPriSup.T trace covers 7 to 40 °C, a temperature span of 33 K. The first recorded maximum occurs at 620 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named MixingValveControl. The source file places it under DHC, Loads, Controls. We used the 101 stored values for senTPriSup.T over the interval 0 to 1,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name disFlo (Flow Distribution), souPri (Boundary p T), TPriHea (Constant), TPriChi (Constant). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel senTSecRet.T covers 293.15 to 298.15 K. At 90 s, the primary value is 280.15 and the companion is 296.15. Their signed difference is -16 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Mixing valve control in change-over mode. The simulated senTPriSup.T channel runs from 280.15 to 313.15 K over 1,000 seconds.
Mixing valve control in change-over mode. The simulated senTPriSup.T channel runs from 280.15 to 313.15 K over 1,000 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 600 to 610 seconds. Subtracting 280.15 from 313.148 gives 32.998 K. Its location brackets the change within one saved interval of 10 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

senTPriSup.T (K)

senTSecRet.T (K)

0

293.15

293.15

90

280.15

296.15

200

280.15

296.15

400

280.15

296.15

600

280.15

296.15

610

313.1485

298.1499

620

313.15

298.15

800

313.15

298.15

1000

313.15

298.15

What to check on site

Distinguish the component characteristic from the installed system response. Record the pressure or temperature on both sides as applicable, the direction of flow and the actuator command. Compare a change at constant demand with one caused by a different load.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.