The recorded bou.ports[1].m_flow channel spans 0.03133 to 0.03907 kg/s in this reference run. It starts at 0.03133 and ends at 0.03133. The first recorded maximum occurs at 46,656 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named MixedAirCO2. The source file places it under Thermal Zones, Detailed. We used the 101 stored values for bou.ports[1].m_flow over the interval 0 to 86,400 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name gaiCO2 (Gain), senCO2 (PPM), CO2Set (Constant), norCO2Set (Gain). The source declares mOut_flow = 47*2/3600*1.2. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel conPI.y starts at 0, ends at 0 and has a recorded range of 0 to 0.2469 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Mixed air room model with CO₂ concentration simulated. The simulated bou.ports[1].m_flow channel runs from 0.03133 to 0.03907 kg/s over 86,400 seconds.
Mixed air room model with CO₂ concentration simulated. The simulated bou.ports[1].m_flow channel runs from 0.03133 to 0.03907 kg/s over 86,400 seconds. Figure by Industry Applied.

Reproduce the calculation

Integrating the signed rate over 86,400 seconds gives a net 2,737 kg. This estimate averages neighbouring stored rates and multiplies by their time separation. Reverse flow reduces the net total. If a process requires gross throughput, calculate forward and reverse transfers separately at the appropriate boundary.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

bou.ports[1].m_flow (kg/s)

conPI.y (source units)

0

0.03133333

0

17280

0.03133333

0

34560

0.03133333

0

45792

0.03133333

0

46656

0.03907097

0.2469458

51840

0.03133333

0

69120

0.03133333

0

86400

0.03133333

0

What to check on site

Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.