The recorded vol.T temperature spans 19.976 °C to 20 °C in this simulation. That is a change of 0.024323 K. The first saved maximum occurs at 0.72 s. The source trace and download retain absolute temperatures in kelvin.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named MSLFlueGasSixComponents. The source file places it under Fluid, Mixing Volumes. We used the 101 stored values for vol.T over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 1 recorded variables. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

The primary channel spends 83.2% of its saved checkpoints at or above 293.138 K, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 293.145 K. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.

Medium for flue gas from the modelica standard library. The simulated vol.T channel runs from 293.126 to 293.15 K over 1 seconds.
Medium for flue gas from the modelica standard library. The simulated vol.T channel runs from 293.126 to 293.15 K over 1 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 0.01 seconds. Subtracting 293.15 from 293.126 gives -0.02396 K. Its location brackets the change within one saved interval of 0.01 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

vol.T (K)

0

293.15

0.01

293.126

0.2

293.1395

0.4

293.1475

0.6

293.1501

0.72

293.1504

0.8

293.1503

1

293.1502

What to check on site

Distinguish the component characteristic from the installed system response. Record the pressure or temperature on both sides as applicable, the direction of flow and the actuator command. Compare a change at constant demand with one caused by a different load.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.