The vol.T trace covers 19.976 to 20 °C, a temperature span of 0.02396 K. The first recorded maximum occurs at 0 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named MSLCombustionAir. The source file places it under Fluid, Mixing Volumes. We used the 101 stored values for vol.T over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name res (Pressure Drop), masFloSou (Mass Flow Source T), bou (Boundary p T), vol (Mixing Volume). The source declares dp_nominal = 10, m_flow_nominal = 10. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The primary channel spends 83.2% of its saved checkpoints at or above 293.138 K, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 293.145 K. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.

Medium for combustion air from the modelica standard library. The simulated vol.T channel runs from 293.126 to 293.15 K over 1 seconds.
Medium for combustion air from the modelica standard library. The simulated vol.T channel runs from 293.126 to 293.15 K over 1 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 0.01 seconds. Subtracting 293.15 from 293.126 gives -0.02396 K. Its location brackets the change within one saved interval of 0.01 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

vol.T (K)

0

293.15

0.01

293.126

0.2

293.1397

0.4

293.1472

0.6

293.1494

0.8

293.1497

1

293.1497

What to check on site

Compare fuel or electrical input with useful heat at a declared delivery boundary. Include the warm-up interval and any period on standby. Separate a temperature setpoint from the measured outlet and keep auxiliary energy in a stated part of the balance.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.