The g trace ranges from -68,649.6 to 0 across 101 saved checkpoints. It begins at 0 and finishes at -68,649.6 after 1 s of test time. The reference export does not state a verified engineering unit for this value. Use its native scale when comparing another run of the same model.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named WaterProperties. The source file places it under Media. We used the 101 stored values for g over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.
The reference file contains 21 recorded variables. Alongside the primary output there are p, X[1], d, eta, h. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.
Compare the recorded channels
The two named channels have separate paths in the model. g begins at 0 and ends at −68,650. h begins at 0 and ends at 4.184e+05. The reference export supplies numerical samples but does not attach a physical unit to these fields. Use the linked model declarations to establish the quantity and units of each channel before calculating a difference or assigning it a physical meaning.
Reproduce the calculation
The largest absolute change between consecutive stored points appears from 0.99 to 1 seconds. Subtracting -67,350 from -68,650 gives -1,300 source units. Its location brackets the change within one saved interval of 0.01 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | g (source units) | h (J/kg) |
|---|---|---|
0 | 0 | 0 |
0.2 | -2991.371 | 83680 |
0.4 | -11696.2 | 167360 |
0.6 | -25749.07 | 251040 |
0.8 | -44828.53 | 334720 |
0.99 | -67349.96 | 414216 |
1 | -68649.59 | 418400 |
What to check on site
Identify which part of the system the selected output represents, and retain the surrounding boundary conditions. Compare the same event and operating duty in both records. Record the equipment configuration if a later change could alter the test result.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Units in the source model
The component declarations identify the scale of the exported variables. In this run, h uses J/kg. Keep the exact channel name and unit together when exporting data to a historian. Read the component definition.
Checking the two recorded channels
At 1 s, g reads -68,649.6 and h reads 418,400 J/kg. Across the run, the second channel ranges from 0 J/kg to 418,400 J/kg. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.