The recorded d channel spans 1.016 to 1.201 source units in this reference run. It starts at 1.201 and ends at 1.016. The first recorded maximum occurs at 0 seconds and the first minimum at 1 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named SteamProperties. The source file places it under Media. We used the 101 stored values for d over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name state_phX (Thermodynamic State), state_psX (Thermodynamic State), ddhp (Der Density By Enthalpy), ddph (Der Density By Pressure). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The two named channels have separate paths in the model. d begins at 1.2013 and ends at 1.0159. f begins at −1.3358e+05 and ends at −5.9201e+05. The reference export supplies numerical samples but does not attach a physical unit to these fields. Use the linked model declarations to establish the quantity and units of each channel before calculating a difference or assigning it a physical meaning.

Media steam properties. The simulated d channel runs from 1.016 to 1.201 source units over 1 seconds.
Media steam properties. The simulated d channel runs from 1.016 to 1.201 source units over 1 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 0.01 seconds. Subtracting 1.201 from 1.199 gives -0.002422 source units. Its location brackets the change within one saved interval of 0.01 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

d (source units)

f (source units)

0

1.201284

-133581.9

0.01

1.198862

-137984.4

0.2

1.156544

-222328.9

0.4

1.116902

-312544.9

0.6

1.080651

-404229.9

0.8

1.047132

-497383.9

1

1.015948

-592006.8

What to check on site

Compare fuel or electrical input with useful heat at a declared delivery boundary. Include the warm-up interval and any period on standby. Separate a temperature setpoint from the measured outlet and keep auxiliary energy in a stated part of the balance.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.